PDE / ADE · OEL / OEB

Home→PDE/ADE · OEL/OEB Profiles → Gadodiamide→

Gadodiamide PDE report and OEL report profile

Project-specific health-based exposure limit and occupational toxicology assessment support. The agreed scope may include PDE/ADE derivation, OEL derivation and OEB/OHC banding, based on the exact substance form, available evidence and intended product or workplace context.

CAS Registry Number
131410-48-5
Molecular formula
C16H26GdN5O8
Molecular weight
573.66 g/mol
Drug class
Gadolinium-based MRI contrast agentlinear non-ionic gadolinium chelate
Mechanism of action
The intact gadolinium chelate is paramagnetic and shortens T1 relaxation times to increase MRI signal intensity in tissues where it distributes. It is a diagnostic contrast complex, and its use is restricted or contraindicated in patients at risk of nephrogenic systemic fibrosis (NSF).
Indications / reported uses
  • Historical contrast-enhancement use for MRI of the central nervous system and selected body regions; gadodiamide is contraindicated or heavily restricted in severe renal impairment in many jurisdictions due to NSF risk. Verify current local availability and product status.

Sources: EMA — Gadolinium-containing contrast agents referral · US DailyMed — OMNISCAN (gadodiamide) · FDA product information

View request basketPrefer email? info@toxwriter.com
PDE / ADE derivationOEL derivationOEB / OHC banding
Assessment scope

PDE/ADE and OEL/OEB assessment

ToxWriter provides project-specific support for Gadodiamide PDE/ADE, OEL and OEB/OHC assessments. This combined profile covers the Gadodiamide Permitted Daily Exposure (PDE) report (the Gadodiamide PDE report); Acceptable Daily Exposure (ADE) is the corresponding health-based daily exposure terminology. It also covers the Gadodiamide Occupational Exposure Limit (OEL) report (the Gadodiamide OEL report). PDE/ADE derivation and workplace exposure assessment are distinct scientific outputs; a band is not a numerical OEL.

Assessment may cover

  • PDE/ADE derivation using relevant toxicological evidence, critical effects, a justified point of departure and adjustment factors.
  • OEL derivation considering relevant hazards, exposure route, duration and workplace conditions.
  • OEB/OHC banding where requested and supported by the evidence; an exposure band is not a numerical OEL.
  • Review of substance identity, evidence quality, uncertainty and data gaps.
PDE/ADE, OEL & OEB/OHC regulatory framework

The EMA HBEL guideline informs PDE/ADE assessments in relevant shared-facility contexts. ECHA and HSE sources address workplace exposure limits; NIOSH provides occupational exposure-banding guidance. The applicable framework depends on the assessment question and jurisdiction.